New Arrival Pd Shielding Enclosure Room

Product Details
Customization: Available
After-sales Service: Online Technical Support
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
501~1000 square meters
  • New Arrival Pd Shielding Enclosure Room
  • New Arrival Pd Shielding Enclosure Room
  • New Arrival Pd Shielding Enclosure Room
  • New Arrival Pd Shielding Enclosure Room
  • New Arrival Pd Shielding Enclosure Room
  • New Arrival Pd Shielding Enclosure Room
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Feature
  • Application
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
HT-PDSR001
Certification
ISO, RoHS
Type
Partial Discharge Shielding Room
Application
Industry
Material
Aluminum
Size
Customize
Ventilation Waveguide Window
300*300mm
Shielding Performance
0.15~1.6MHz ≥ 60dB
Background Noise
≤2PC (When The Test Object Is Not Energized)
Reverberation Time
T ≤5s (at 400Hz)
Transport Package
Carton + Wooden
Specification
Custom
Trademark
OEM/ODM
Origin
Guangdong

Packaging & Delivery

Package Size
25.00cm * 33.00cm * 3.00cm
Package Gross Weight
0.500kg
Lead Time
15 days (1 - 10 Pieces)
To be negotiated ( > 10 Pieces)

Product Description

New Arrival PD Shielding Enclosure Room 
 
Product Description

 

A partial discharge shielding room (PDSR) is a specialized environment designed to test and measure partial discharges in electrical equipment. Partial discharges are localized dielectric breakdowns that occur in high voltage insulation systems and can be indicative of insulation defects. Proper testing and measurement of partial discharges are crucial for ensuring the reliability and longevity of high voltage electrical equipment, such as transformers, cables, and switchgear.

New Arrival Pd Shielding Enclosure RoomNew Arrival Pd Shielding Enclosure RoomNew Arrival Pd Shielding Enclosure RoomNew Arrival Pd Shielding Enclosure Room

Specification
Shielding Performance: 0.15~1.6MHz ≥60dB
Background Noise ≤2Pc (when the test object is not energized)
Reverberation Time t ≤5s (at 400Hz)
Application Suitable for partial discharge tests or impulse tests for cables, transformers, instrument transformers, switches, and substations with voltage levels of 35KV and below.
 
Feature

 

  1. Shielding Body:

    • Made of high-quality galvanized steel sheets (punched with micro-holes), processed into modular frames, and fixed with conductive liners using bolts to form a six-sided shell. It ensures reliable electromagnetic sealing and facilitates convenient assembly and disassembly.
  2. Shielding Door:

    • The main shielding door (for the entry and exit of test objects) adopts an airtight sliding structure. The door operates with variable frequency speed regulation and PLC program control, featuring touch screen operation, smooth and noise-free opening, anti-pinch safety functions, and customizable exterior decoration according to customer requirements.
    • The smaller shielding door (for personnel entry and exit) can be customized for manual or electric operation as per customer needs.
  3. Shielding Accessories:

    • Ventilation waveguide windows, filters, and dedicated waveguide tubes for shielding.
  4. Control Room:

    • Constructed with a steel frame or steel plate assembly structure. To meet the test requirements of the test objects and ensure personnel safety, a shielding observation window is installed facing the test area for monitoring the operation of the test objects. Interior decoration can be customized according to customer requirements.
Application

 

 
  1. Testing Electrical Equipment:

    • Cables: Ensuring the integrity of insulation in power and communication cables by detecting partial discharges that indicate weak points or defects.
    • Transformers: Testing power and distribution transformers to detect insulation degradation or manufacturing defects.
    • Instrument Transformers (Current and Voltage Transformers): Assessing the insulation quality and detecting potential partial discharges in instrument transformers used in high-voltage applications.
    • Switchgear: Evaluating the insulation condition in switchgear to prevent failures and ensure reliable operation.
    • Motors and Generators: Checking for partial discharges in the stator windings of large motors and generators, which can indicate insulation weaknesses.
  2. Quality Control in Manufacturing:

    • New Product Testing: Manufacturers of high-voltage equipment use PDSRs to conduct routine tests on new products before they leave the factory, ensuring they meet required standards and specifications.
    • Prototype Testing: During the development of new designs, prototypes are tested for partial discharge to validate their insulation performance and make necessary improvements.
  3. Maintenance and Diagnostics:

    • Condition Monitoring: Regular testing of in-service equipment to monitor the condition of insulation and identify any emerging issues before they lead to failures.
    • Predictive Maintenance: Using PD measurements as part of a predictive maintenance program to schedule repairs or replacements before catastrophic failures occur, thereby reducing downtime and maintenance costs.
  4. Research and Development:

    • Material Testing: Investigating the performance of new insulating materials under high-voltage conditions to develop better, more reliable products.
    • Design Optimization: Testing different design configurations to optimize the performance and reliability of high-voltage equipment.
  5. Compliance and Certification:

    • Standards Compliance: Ensuring that electrical equipment complies with international and industry standards for partial discharge, such as IEC 60270.
    • Certification: Gaining certification for high-voltage equipment by demonstrating compliance with regulatory and industry standards through rigorous PD testing.

This equiment is suitable for partial discharge test or impulse test of cables, transformers, transformer switches and power stations with voltage level 35KV and below.

Company Profile

Shenzhen Huntoo Technology Co., Ltd. is a manufacturer of rfid, emf, radiation shielding and Thermal conductive electric insulating materials and end products with well-equipped testing facilities and strong technical force.

With a wide range, good quality, reasonable prices and stylish designs, our products are extensively used in consumer electronics, anti-RFID scanning, radiation protection, electromagnetic shielding and other industries.

Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs.
We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!

 

 
Packaging & Shipping

 

New Arrival Pd Shielding Enclosure Room

Any means of transportation supported, by air, by sea or express can be chosen as requests

 

 

FAQ

1. Who are we?
We are based in Guangdong, China, start from 2015,sell to Eastern Europe(30.00%),North America(15.00%),Western Europe(15.00%),Southern Europe(10.00%),Northern Europe(10.00%),South America(5.00%),South Asia(5.00%),Southeast Asia(5.00%),Oceania(2.00%),Mid East(1.00%),Africa(1.00%),Central America(1.00%). There are total about 51-100 people in our office.

2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;


3.What can you buy from us?
RFID EMI EMF Shielding Fabric,EMF Protection Clothing,EMF Protection Hats,EMF Protection Blankets,RFID Blocking Card Sleeve

4. Why should you buy from us not from other suppliers?
We are mainly specialized in rfid, emi, radiation shielding and Thermal conductive electric insulating materials and equiments for 10 years. Precision equipment & professional quality control system provide customers high quality products with reasonable price.

 

 

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier